text.skipToContent text.skipToNavigation

Motherboard 2000 Left Hand Medys

2189553
2154256 45433448
New
X-Ray
GE Healthcare
GE Healthcare
GE HealthCare
N/A
Outright
Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Critical to Quality (CTQ) characteristics which have customer impact like diagnostic accuracy and patient comfort are provided
  • Designed according to regulations like IEC601-1 International Electro technical Commission, Code of Federal Regulations, HEW Performance Standards for Ionizing Radiation Emitting Products 21 CFR and UL 2601 or UL 187 UL Safety Standards
  • Meets all the performance requirements when oscillating the grid horizontally, vertically and all orientations in between
  • Compatible for usage in the radiographic tables and radiographic wall stands

Product Overview

The MB 2000 Left Hand Medys comes as a part of a radiographic system used for imaging method diagnosis using X-Rays. It is a left hand loading reciprocating Bucky. A stream of electrons produced by X-Ray tube is accelerated to high velocities by an external high-voltage supply and collide with the target anode in the tube. The beam formed is focused on the patient, and X-Rays emerging from the patient carry the image information which can be stored on a film. The Bucky oscillates the grid during radiographic exposures to eliminate visible grid lines in radiographs. It also provides support for the ion chamber, cassette tray, and grid. It is designed for left hand loading, but is also available for right hand loading to allow the cassette tray loading from either side of the Bucky. It also consists of a single design that allows the Bucky to be configured for each side loading configuration or it consists of 2 distinct Bucky designs to achieve both loading configurations. If one design is utilized, the maximum amount of time to configure the Bucky loading shall not exceed 15 minutes.

  • Additional Features

    • Field Replacement Unit (FRU) - can be quickly and easily removed or replaced

    Compatible Products

    Precision 500D

    Precision 500D

    Robust, digital performance at an efficient dose
    It starts with the imaging chain, which features a 12-bit CCD-based camera.Then there’s AutoEx, which automatically adjusts key image-acquisition parameters in real time for optimum quality. Meanwhile, closed-loop Automatic Brightness Control and patented extended Dynamic Range circuitry maintain contrast and minimize blooming.

    Equivalent Part :

    Below is more information on the equivalent parts. Parts without a hyperlink are listed for reference only and are not available for purchase online.

    Equivalent partPart Details
    2154256 LIEBEL BUCKY LEFT SIDE LOAD
    45433448 BUCKY LIEBEL 248051D

    Return And Exchange

    GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

    Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.