text.skipToContent text.skipToNavigation

Airway Pressure Gauge BCG Tester Breathing System Assembly

1406-8206-000
New
Anesthesia Delivery
GE Healthcare
Datex-Ohmeda
GE HealthCare
N/A
Outright
Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Easy to install
  • Easy to remove
  • Non corrosion part
  • Flexible

Product Overview

Airway Pressure Gauge BCG tester is used in breathing systems. The accuracy of the absorber airway pressure gauge can be checked by using a low-pressure test device (digital manometer or test gauge), a low-pressure supply source (typically a syringe) and an airway pressure gauge test adapter. It ensures that the pressure gauge is zero, connects a low-pressure supply source (syringe) to one of the open tubes of the test adapter, connects the test adapter plug to the pressure gauge port on the absorber bulkhead and a low-pressure test device to the remaining open tube of the test adapter. It also adjusts the pressure source to the following pressures as read on the test device and the airway pressure gauge should read within the values indicated. Merely attach a gauge to the O₂ primary regulator test port (On pipeline only machines, attach the gauge to a plugged 6-mm O₂ port at the front of the pneumatic manifold shown at left). This gauge is used in many systems such as MS DASH 4000, ARC Aespire View, MS PDM, ARC Aestiva 3000, MIC Panda™ iRES Warmer, ARC Aespire 7900 etc.,

Compatible Products

Aestiva WU_0042

Aestiva WU_0042

CardioServ

CardioServ

Return And Exchange

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.